HIGH VOLTAGE INSULATION TESTER IR5051
Measure Solar PV System Insulation Resistance Safely and Accurately While Generating.
Maximum 5kV Test Voltage – Up to 10 TΩ of Insulation Resistance Testing.
The IR5051 is a compact, lightweight, high-voltage insulation resistance tester capable of outputting up to 5 kV. Its unique measurement technology enables stable measurements of up to 10 TΩ. In addition, the IR5051 is capable of testing the insulation resistance of solar PV systems during power generation, and has a CAT III 2000 V safety rating to allow testing of 2000 V PV systems.
Key Features
- Measure solar PV system insulation resistance safely and accurately while generating
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5000 V from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- Automatically calculated and displayed insulation diagnostics (PI, DAR, and DD)
- Data memory functions increase your work efficiency by eliminating human errors from manual reporting.
- Selectable Interface Compatibility: Offers both wireless and USB connectivity options.
- Compact and lightweight, equipped with an IP65-rated carrying case
Basic specifications
| Measurement parameters | • Insulation resistance • PV insulation resistance • Leakage current • Voltage • Capacitance (DD function) |
|---|---|
| Max. rated voltage to terminals | 1000 V AC, 2000 V DC |
| Max. rated voltage to ground | 1000 V (CAT IV), 600 V (CAT III) |
| Operating temperature and humidity range | -20°C to 50 °C (*1) (no condensation) |
| Storage temperature and humidity range | -25°C to 65°C (-13°F to 149°F), less than 80% RH (no condensation) |
| Dustproof/waterproof | IP40 (with protector attached, excluding terminals) IP65 (CARRYING CASE C0212) |
| Standards | EN61010 (safety), EN61326 (EMC), IEC 61557-1, IEC 61557-2 (Insulation resistance tester) |
| Power supply | • LR6 (AA) alkaline battery × 8 • HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery × 8 |
| Continuous operating time (*2) | Approx. 5 hours without Z3210 installed; approx. 4 hours with Z3210 installed and using wireless communication |
| Dimensions and weight | 195 mm (7.68 in.) W × 254 mm (10 in.) H × 89 mm (3.50 in.) D, 1.7 kg (59.97 oz.) (including batteries) |
| Included accessories | Test lead L9850-01 ×1, Test lead L9850-02 ×1, Test lead L9850-03 ×1, Alligator clip L9851-01 ×1, Alligator clip L9851-02 ×1, Alligator clip L9851-03 ×1, Test pin set L9852 ×1, Carrying Case C0212 ×1, LR6 Alkaline battery ×8, Instruction manual ×1, Operating precautions ×1, Wireless adapter Z3210(IR5051-90 only) |
- *1:-20°C to 40°C (-4°F to 104°F), less than 80% RH , 40°C to 45°C (104°F to 113°F), less than 60% RH , 45°C to 50°C (113°F to 122°F), less than 50% RH
- *2:When using alkaline batteries, 5 kV generated, +/- terminals open, backlight off and comparator off
Functions
| Insulation diagnosis | PI, DAR, DD, SV, Ramp, Timer (*3) |
|---|---|
| Others | Battery charge indicator, live circuit indicator, automatic power save, automatic discharge, backlight, buzzer, manual recording, logging recording, temperature and humidity input, elapsed time display, clock, filter, hardware filter, data-hold, system reset, USB communication (only when DT4900-01 is installed), wireless communication (only when Z3210 is installed), comparator, resistance gauge display, switching of insulation diagnosis function, breakdown cut-off, negative voltage notification |
- *3:Only for can be set in the PV insulation resistance function
PV insulation resistance
| Test voltage range | DC 250 V to 2.00 kV | ||
|---|---|---|---|
| Test voltage presets | 500 V, 1 kV, 1.5 kV | ||
| User-set test voltage | 250 V to 1 kV: in 10 V increments; 1 kV to 2 kV: in 25 V increments | ||
| Test voltage preset | 500 V | 1000 V | 1500 V |
| Guaranteed accuracy range (1) | 0.00 MΩ to 5.00 GΩ ±5% rdg ±5 dgt | 0.00 MΩ to 10.00 GΩ ±5% rdg ±5 dgt | 0.00 MΩ to 20.0 GΩ ±5% rdg ±5 dgt |
| Guaranteed accuracy range (2) | 5.01 GΩ to 100 GΩ ±20% rdg | 10.1 GΩ to 100 GΩ ±20% rdg | 20.1 GΩ to 100 GΩ ±20% rdg |
| Rated current | [Test voltage] / [20 MΩ] | ||
| Open-circuit voltage | From 0% to 10% of test voltage | ||
| Short-circuit current | 2 mA or less | ||
| Possible number of measurements | 1000 times or more on one set of fully-charged batteries | ||
Insulation resistance measurement
| Test voltage range | DC 250 V to 5.20 kV DC | ||||
|---|---|---|---|---|---|
| User-set test voltage | 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments | ||||
| Test voltage preset | 250 V | 500 V | 1000 V | 2500 V | 5000 V |
| Guaranteed accuracy range (1) | 0.00 MΩ〜2.50 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜5.00 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜10.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜25.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜50.0 GΩ ±5% rdg ±5 dgt |
| Guaranteed accuracy range (2) | 2.51 GΩ〜500 GΩ ±20% rdg | 5.01 GΩ〜1.00 TΩ ±20% rdg | 10.1 GΩ〜2.00 TΩ ±20% rdg | 25.1 GΩ〜5.00 TΩ ±20% rdg | 50.1 GΩ〜10.00 TΩ ±20% rdg |
| Rated current | 1 mA to 1.2 mA | ||||
| Short-circuit current | 2 mA or less | ||||
| Possible number of measurements | 200 times or more on one set of fully-charged batteries | ||||
Leakage current measurement
| Measurement range (auto) | 10 nA | 100 nA | 1000 nA | 10 μA | 100 μA | 1 mA |
|---|---|---|---|---|---|---|
| Display range | 0.00 nA to 9.99 nA | 9.0 nA to 99.9 nA | 90 nA to 999 nA | 0.90 μA to 9.99 μA | 9.0 μA to 99.9 μA | 90 μA to 999 μA (*4) 0.90 mA to 3.00 mA (*5) |
| Resolution | 0.01 nA | 0.1 nA | 1 nA | 0.01 μA | 0.1 μA | *4: 1 μA *5: 0.01 mA |
Voltage measurement
| Guaranteed accuracy range | 30 V to 1,000 V AC (45 Hz to 65 Hz), ±10 V to ±2,000 V DC |
|---|---|
| Accuracy | ±3% rdg. ±3 dgt. |
| Input resistance | 500 kΩ or more (DC, 45 Hz to 65 Hz) |
| Overload protection | 1100 V AC (1 min., between +/- terminals) 2200 V DC (1 min., between +/- terminals) |
Capacitance measurement
| Accuracy | ±10% rdg. ±5 nF (guaranteed accuracy range: 10.0 nF to 25.0 µF) | ||
|---|---|---|---|
| Measurement range | 100 nF | 1000 nF | 10 μF |
| Display range | 0.0 nF to 99.9 nF | 100 nF to 999 nF | 1.00 μF to 9.99 μF (*6) 10.0 μF to 25.0 μF (*7) |
| Resolution | 0.1 nF | 1 nF | *6: 0.01 μF *7: 0.1 μF |
-
Occupational Safety (K3), Personal Protection & Health
Gembok Koper Master Lock 4684TCOL Kombinasi 30mm
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 9120EURT – Gembok Tas & Koper Aluminium 20mm (2 Pack)
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock Fusion 20mm 4630EURTAST – Gembok Keamanan untuk Koper & Tas (2 Pcs)
Read More -
Occupational Safety (K3), Personal Protection & Health
MasterLock Steering Wheels Locks 249DAT Red – Kunci Setir Mobil
Read More -
Occupational Safety (K3), Personal Protection & Health
MasterLock High Security Chains 8016D – Rantai Keamanan Baja
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 2250EURD 50mm wide solid brass body padlock with shrouded shackle
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 2240EURD Solid Brass Padlock Hardened Steel Shackle, Gembok Kuningan
Read More -
Helmets and light work hats
TRUSCO Helmet, Front Peak Type, White, With grooves to prevent unpleasant rain drops 381-7814 DPM-0169W
Read More -
Chemical and solvent resistant gloves
Ansell Oil and Chemical Resistant Nitrile Thick Gloves Alphatec Sorbex 37-165 Medium Size
Read More
Kami adalah perusahaan yang bergerak di bidang industrial supply company, berdiri sejak tahun 2010.
Menyediakan berbagai kebutuhan industri dan bisnis, mulai dari produk MRO (Maintenance, Repair, and Operation), alat keselamatan, perkakas tangan dan elektrik, alat kebersihan, hingga alat ukur dan analisa listrik
Cilegon Office & KARCHER Service Center:
Jl Boulevard Raya no 36-38. Ruko Grand Cilegon Resident Cibeber. Cilegon-Banten, Indonesia 4242
Phone / fax : 0254 375765 / 0254 387163
Surabaya Office:
Jl. Puri Kencana Karah B-5 Surabaya 60232
Phone : 031 825 31779
E-mail : www.kawanbaruteknik@ymail.com