DIGITAL MULTIMETER DT4281
World’s Premier Digital Multimeter. Superior Accuracy and High Response, Topped with Safety Terminal Shutters
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters. The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications.
CAT IV 600 V, CAT III 1000 V
Key Features
- 60000 count, 5-digit display, high-resolution measurements
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Dual display lets you check voltage and frequency simultaneously
Basic specifications
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | |||||
|---|---|---|---|---|---|---|
| AC Voltage* range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz – 100 kHz Basic accuracy 45 – 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|||||
| DC + AC Voltage* range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz – 100 kHz Basic accuracy 45 – 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|||||
| Resistance range | 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt. | |||||
| DC Current range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.05 % rdg. ±5 dgt. |
|||||
| AC Current* range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy 45 – 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz – 20 kHz (at 600 μA to 600 mA range) |
|||||
| AC Current* range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges Add the Clamp on probe accuracy to Basic accuracy 40 – 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3) |
|||||
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|||||
| Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. | |||||
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more | |||||
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages | |||||
| Frequency range | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
|||||
| dB conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV) |
|||||
| Temperature (thermocouples) | K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C |
|||||
| Other functions | Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion | |||||
| Display | Main and sub displays: 5-digits LCD, max. 60000 digits | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) | |||||
| Power supply | LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours | |||||
| Dimensions and mass | 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) | |||||
| Included accessories | Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4 | |||||
- *Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed.
-
Occupational Safety (K3), Personal Protection & Health
Gembok Koper Master Lock 4684TCOL Kombinasi 30mm
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 9120EURT – Gembok Tas & Koper Aluminium 20mm (2 Pack)
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock Fusion 20mm 4630EURTAST – Gembok Keamanan untuk Koper & Tas (2 Pcs)
Read More -
Occupational Safety (K3), Personal Protection & Health
MasterLock Steering Wheels Locks 249DAT Red – Kunci Setir Mobil
Read More -
Occupational Safety (K3), Personal Protection & Health
MasterLock High Security Chains 8016D – Rantai Keamanan Baja
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 2250EURD 50mm wide solid brass body padlock with shrouded shackle
Read More -
Occupational Safety (K3), Personal Protection & Health
Master Lock 2240EURD Solid Brass Padlock Hardened Steel Shackle, Gembok Kuningan
Read More -
Helmets and light work hats
TRUSCO Helmet, Front Peak Type, White, With grooves to prevent unpleasant rain drops 381-7814 DPM-0169W
Read More -
Chemical and solvent resistant gloves
Ansell Oil and Chemical Resistant Nitrile Thick Gloves Alphatec Sorbex 37-165 Medium Size
Read More
Kami adalah perusahaan yang bergerak di bidang industrial supply company, berdiri sejak tahun 2010.
Menyediakan berbagai kebutuhan industri dan bisnis, mulai dari produk MRO (Maintenance, Repair, and Operation), alat keselamatan, perkakas tangan dan elektrik, alat kebersihan, hingga alat ukur dan analisa listrik
Cilegon Office & KARCHER Service Center:
Jl Boulevard Raya no 36-38. Ruko Grand Cilegon Resident Cibeber. Cilegon-Banten, Indonesia 4242
Phone / fax : 0254 375765 / 0254 387163
Surabaya Office:
Jl. Puri Kencana Karah B-5 Surabaya 60232
Phone : 031 825 31779
E-mail : www.kawanbaruteknik@ymail.com