AC/DC CLAMP METER CM4375-50

True RMS 2000 A AC/DC Clamp Meter for the Toughest Situations
With DMM Functions that Deliver Top Safety

Dapatkan Penawaran

Diskusi dan Tanya Harga

Features

DC High V Probe Mode

– Enables high voltage measurement up to CAT III 2000 V
– Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)

Wireless communication capability for even greater convenience

Wireless support

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

Excel® Direct Input Function (*1)

Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.

Helping personnel analyze issues in the field

Harmonic measurement

When combined with GENNECT Cross (*2), you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

Convenient for repeated measurement and recording tasks!

Automatic hold function

In addition to being convenient when the display cannot be seen during measurement, when the measurement value is stabilized, the display value is automatically held until the next measurement, which is very convenient for repeated measurement and recording tasks.

Assess transient currents at motor startup

The clamp meters can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.
The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate
measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.

Basic specifications

Accuracy guaranteed: 1 year

DC Current range 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
AC Current range 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A)
Crest factor 600.0 A range: 3 or less
2000 A range: 2.84 or less
DC+AC Current range 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 600 A)
DC Voltage range 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
AC Voltage range 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
DC+AC Voltage range 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance range 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Capacitance range 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature (K) -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
Voltage detection Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
Harmonic levels [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other functions DC power, Continuity check, Diode check, Automatic AC/DC detection, Pass/fail judgement function of DC A and DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment, etc.
Dustproof, waterproof IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)
Power supply LR03 Alkaline battery ×2
Continuous use: 40 hr (without Z3210 installed), 24 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value
Core jaw diameter φ55 mm (2.17 in), Jaw dimension: 92 mm (3.62 in) W×18 mm (0.71 in) D
Dimensions and mass 65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz)
Included accessories Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual×2, Operating Precautions ×1

Kami adalah perusahaan yang bergerak di bidang industrial supply company, berdiri sejak tahun 2010. 

Menyediakan berbagai kebutuhan industri dan bisnis, mulai dari produk MRO (Maintenance, Repair, and Operation), alat keselamatan, perkakas tangan dan elektrik, alat kebersihan, hingga alat ukur dan analisa listrik

Cilegon Office & KARCHER Service Center:
Jl Boulevard Raya no 36-38. Ruko Grand Cilegon Resident Cibeber. Cilegon-Banten, Indonesia 4242
Phone / fax  : 0254 375765 / 0254 387163

Surabaya Office:
Jl. Puri Kencana Karah B-5 Surabaya 60232
Phone : 031 825 31779 

Chat Kami